RE-VERBER-RAY RVA SERIES TUBE HEATER (Manufactured 05/04/95 to 09/95)
Contact the factory for additional parts.
Common Components
|
||
| Part Description | Original Part Number |
Replacement |
| Fan | TP-55A | TP-55A |
| Pressure Switches | See Below | See Below |
| Circuit Board1,2 | TP-211 | TP-211A2 |
| Wire Harness (Glo-Bar and Flame Rod Only) | TP-214 and TP-222A | TP-214 and TP-222A |
| Relay (Note: This factory installed option is not on all units) | HLRB | TP-825 |
| Ignition Device | TP-50 | TP-50A |
| 50-100MBH Burner | TP-200A | TP-3072 |
| 125-200MBH Burner | TP-201 | TP-201B |
| Natural Gas Valve | TP-840 | TP-840A |
| Propane Gas Valve | TP-841 | TP-841A |
| Transformer | TP-826 | TP-826 |
| Indicator Lights | TP-828 | TP-828 |
| Flame Rod (whole kit=TP-FRK)3 | N/A | Add TP-FRK |
| 16″ Burner Tube | TP-202 | TP-380 |
| Combustion Chamber4, 50-125MBH (Aluminized Steel) | TP-26A | TP-26A |
| Combustion Chamber4, 150-200MBH (Titanium Coated Steel) | TP-26B | TP-26B |
| Combustion Chamber4, 75-150MBH (Stainless Steel) | TP-26E | TP-26E |
| Radiant Tubes | TP-26A | TP-26A |
| 10 ft. Reflector Section | TP-20C | TP-20C |
| Baffle | TP-65I | TP-65I |
1 Cross Reference Number (on unit): Mark 17X-24.
2 Circuit board replacement requires the rewiring of the flame rod into remote sense. Consult the factory for assistance.
3 TP-FRK includes the gasket (TP-221), flame rod (TP-222), and flame rod wire (TP-222A).
4 Refers to the first 10′ section of tubing downstream of burner.
Pressure Switches |
|||||
| BTU/H Range (x1000) | 50-100 | 125-150 | 175 | 200 | |
| Switch 15 | Part Number | TP-264B | TP-264D | TP-264D | TP-264C |
| X-Ref., IS220- | -10051F5166 | -20051F5170 | -20051F5170 | -43051F5172 | |
| Normal Setting | Open | Open | Open | Open | |
| P. S. Tube Set | TP-AK3 | TP-AK3 | TP-AK3 | TP-AK3 | |
| Switch 25 | Part Number | TP-260F | TP-260F | TP-260G | TP-260G |
| X-Ref., IS220- | -62502F5176 | -62502F5176 | -62052F5175 | -62052F5175 | |
| Normal Setting | Closed | Closed | Closed | Closed | |
| P. S. Tube Set | TP-AK4 | TP-AK4 | TP-AK4 | TP-AK4 | |
5 Pressure switch #1 is electrically first in the series, and pressure switch #2 is electrically second in the series.