Factory Direct Re-Verber-Ray Replacement Parts

USE CODE 'SUMMER5' FOR 5% OFF

Shopping cart

Pick List

Re-Verber-Ray Tube Heater Parts

Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.

 

Charts

RE-VERBER-RAY DRV SERIES TUBE HEATER (Manufactured 01/91 to 12/01)

Reference the Installation Manual for additional parts. Download

Common Components

 

Part Description Original
Part Number

Replacement
Part Number

FanV-301,V-302,V-303V-301,V-302,V-303
Normally Open Pressure Switch (Exhaust)V-65V-65
Normally Closed Pressure Switch (Burner)V-68V-68
Glo-BarV-50V-50
Circuit Board2See BelowSee Below
Burner TP-48 TP-48
Natural Gas ValveV-36V-36
Propane Gas ValveV-36AV-36A
Wire HarnessTP-78CTP-78C
Burner HousingTP-42TP-42
16″ Burner TubeTP-8CTP-8C
First 10 ft. TubeTP-26BTP-26B
10 ft. Reflector SectionTP-20CTP-20C
Indicator LightsV-22V-22

 

Pressure Switches

 

Switch 11

 

Switch 21,2

DRP Part NumberV-68V-65
Cross Reference Number (on unit)FS6100A-1937FS4450-808
Normal SettingClosedOpen
Pressure Switch Tube SetV-63V-63

1 Pressure switch #1 (burner) is electrically first in series, and pressure switch #2 (exhaust) is second in series.

2 Single pressure swithc models receive this switch. Dual pressure switch models receive both switches.

Circuit Boards

 

Mfg. 1991-05/15/01

 

Mfg. 05/15/01-12/01

Original Circuit BoardTP-78ATP-78D
Cross Reference Number (on unit)Mark 17X-117Mark 17DX-117
Wire HarnessTP-78C3TP-78C and TP-390
Replacement BoardTP-78D3TP-78D
Adaptor3TP-3903N/A

 

3 Use TP-390 adaptor to attach replacement board TP-78D to original wiring harness V-78.