Re-Verber-Ray Tube Heater Parts

Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.

 

Charts

RE-VERBER-RAY DTH(S)-2 SERIES TUBE HEATER (Manufactured 1988 to 1989)

Common Components

 

Part Description Original
Part Number

Replacement
Part Number

Fan TP-55A TP-55A
Normally Open Pressure Switch (Burner) TP-61B TP-264B
Normally Closed Pressure Switch (Exhaust) TP-60B TP-60D
Radiant Sensor TP-64 TP-64
Glo-Bar TP-50 TP-50A
Circuit Board TP-77 Consult Factory*
Burner TP-48 TP-48
Natural Gas Valve TP-36A or TP-36B Consult Factory**
Propane Gas Valve TP-36C Consult Factory**
Burner Housing TP-42 TP-42
16″ Burner Tube TP-6A TP-6A
First 10 ft. Tube1 TP-8D or TP-26B TP-8D or TP-26B
10 ft. Reflector Section2,3 TP-20A or TP-20C TP-20A or TP-20C
Downstream Reflector Section(s) (DTH only)2 TP-20B TP-20B

1 Use TP-8D for DTH Series. Use TP-26B for DTHS Series.

2 The first 10 ft. section of reflector differs from the remaining 10 ft. downstream sections of reflector for the DTH Series only. Use TP-20A for the first 10 ft. section of reflector and TP-20B for the remaining sections.

3 Use TP-20C for DTHS Series.

* The original circuit board TP-77 (discontinued) must be replaced with TP-78D circuit board, TP-390 adapter, and TP-78B wire harness. A new valve is also required. Consult factory.

** When replacing a TP-36A (used on Nat. Gas, 125 MBH), use TP-107. When replacing a TP-36B (used on Nat. Gas, 150 MBH), use TP-79. When replacing the TP-36C (used on Propane, 125 & 150 MBH), use TP-107P. When replacing the gas valve, the circuit board must also be replaced.

 

Circuit Boards

Part Description Part Number
Original Circuit Board TP-77
Cross Reference Number (on unit) 5001A-1
Harness TP-78B
Replacement Board TP-78D
Adaptor4 TP-3902

4 Use TP-390 adaptor to attach replacement board TP-78D to original wiring harness TP-78B.