Factory Direct Re-Verber-Ray Replacement Parts
Current processing time is 3-5 business days. Due to delays with our shipping partners, delivery times can not be guaranteed.
USE CODE 'WINTER10' FOR 10% OFF
Re-Verber-Ray Tube Heater Parts
Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.
RE-VERBER-RAY DTH(S)-3 SERIES TUBE HEATER (Manufactured 1990 to 1994)
Common Components
|
||
| Part Description | Original Part Number |
Replacement |
| Fan | TP-55A | TP-55A |
| Normally Open Pressure Switch (Burner) | TP-61B | TP-264B |
| Normally Closed Pressure Switch (Exhaust) | TP-60B | TP-60D |
| Glo-Bar | TP-50 | TP-50A |
| Circuit Board5 | TP-78A | TP-78D and TP-390 |
| Burner | TP-48 | TP-48 |
| Natural Gas Valve | TP-79 | TP-79 |
| Propane Gas Valve | TP-107P | TP-107P |
| Wire Harness | TP-78B | TP-78B |
| Burner Housing | TP-42 | TP-42 |
| 16″ Burner Tube | TP-8C | TP-8C |
| First 10 ft. Tube1 | TP-8E or TP-26B | TP-8E or TP-26B |
| 10 ft. Reflector Section2,3 | TP-20A or TP-20C | TP-20A or TP-20C |
| Downstream Reflector Section(s) (DTH only)2 | TP-20B | TP-20B |
1 Use TP-8E for DTH Series. Use TP-26B for DTHS Series.
2 The first 10 ft. section of reflector differs from the remaining 10 ft. downstream sections of reflector for the DTH Series only. Use TP-20A for the first 10 ft. section of reflector and TP-20B for the remaining sections.
3 Use TP-20C for DTHS Series.
Pressure Switches |
Switch 14 |
Switch 24 |
| DRP Part Number | TP-264B | TP-60D |
| Cross Reference Number (on unit) | IS22010051F5166 | FS6628-1173 |
| Normal Setting | Open | Closed |
| Pressure Switch Tube Set | TP-51A + TP-56C | TP-AK3 |
4 Pressure switch #1 is electrically first in series, and pressure switch #2 is second in series.
Circuit Boards |
|
| Part Description | Part Number |
| Original Circuit Board | TP-78A |
| Cross Reference Number (on unit) | MARK 17X-117 |
| Harness | TP-78B |
| Replacement Board | TP-78D |
| Adaptor5 | TP-3905 |
5 Use TP-390 adaptor to attach replacement board TP-78D to original wiring harness TP-78B.