Factory Direct Re-Verber-Ray Replacement Parts

Current processing time is 1-2 business days. Due to delays with our shipping partners, delivery times can not be guaranteed.

USE CODE 'SPRING10' FOR 10% OFF

Shopping cart

Pick List

Re-Verber-Ray Tube Heater Parts

Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.

 

Charts

RE-VERBER-RAY DX SERIES TUBE HEATER (Manufactured 05/04/95 to 09/95)

Reference the Installation Manual for additional parts. Download

Common Components

 

Part Description Original
Part Number

Replacement
Part Number

Fan TP-55A TP-55A
Pressure Switches See Below See Below
Circuit Board1 TP-78A TP-78D2,3 and TP-390
Wire Harness TP-78B TP-78B
Ignition Device TP-50 TP-50A
50-100 MBH Burner TP-200 TP-3072
125 MBH Burner TP-201 TP-3072
150-200 MBH Burner TP-201 TP-201B
Natural Gas Valve TP-209 TP-240
Propane Gas Valve TP-209P TP-241
Flame Rod (see TP-FRK for full flame rod kit) TP-222 TP-222
16″ Burner Tube TP-202 TP-380
Combustion Chamber4, 50-125 MBH (Aluminized Steel) TP-26A TP-26A
Combustion Chamber4, 150-200 MBH (Titanium Coated Steel) TP-26B TP-26B
Combustion Chamber4, 75-150 MBH (Stainless Steel) TP-26E TP-26E
Radiant Tubes TP-26A TP-26A
10 ft. Reflector Section TP-20C TP-20C
Baffle TP-65I TP-65I

 

1 Cross Reference Number (on unit): Mark 17X-117.

2 Use TP-390 adaptor to attach the replacement board to the original harness.

3 If flame sense problems exist, consult factory for remote sense wiring assistance.

4 Refers to the first 10′ section of tubing downstream of burner.

Pressure Switches

BTU/H Range (x1000) 50-100 125-150 175 200
Switch 15 Part Number TP-264B TP-264D TP-264D TP-264C
X-Ref., IS220- -10051F5166 -20051F5170 -20051F5170 -43051F5172
Normal Setting Open Open Open Open
P. S. Tube Set TP-AK3 TP-AK3 TP-AK3 TP-AK3
Switch 25 Part Number TP-260F TP-260F TP-260G TP-260G
X-Ref., IS220- -62502F5176 -62502F5176 -62052F5175 -62052F5175
Normal Setting Closed Closed Closed Closed
P. S. Tube Set TP-AK4 TP-AK4 TP-AK4 TP-AK4

5 Pressure switch #1 is electrically first in the series, and pressure switch #2 is electrically second in the series.