Re-Verber-Ray Tube Heater Parts

Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.

 

Charts

RE-VERBER-RAY DX SERIES TUBE HEATER (Manufactured 09/95 to 08/00)

Reference the Installation Manual for additional parts. Download

Common Components

 

Part Description Original
Part Number

Replacement
Part Number

FanTP-55ATP-55A
Pressure SwitchesSee BelowSee Below
Circuit Board1TP-78ATP-351A2,3 and TP-390
Wire HarnessTP-215ATP-3523
Ignition DeviceTP-50TP-50A
50-100MBH BurnerTP-200TP-3072
125MBH BurnerTP-201TP-3072
150-200MBH BurnerTP-201TP-201B
Natural Gas ValveTP-209TP-240
Propane Gas ValveTP-209PTP-241
Flame Rod (see TP-FRK for full flame rod kit)TP-222TP-222
16″ Burner TubeTP-202TP-380
Combustion Chamber4, 50-125MBH (Aluminized Steel)TP-26ATP-26A
Combustion Chamber4, 150-200MBH (Titanium Coated Steel)TP-26BTP-26B
Combustion Chamber4, 75-150MBH (Stainless Steel)TP-26ETP-26E
Radiant TubesTP-26ATP-26A
10 ft. Reflector SectionTP-20CTP-20C
BaffleTP-65ITP-65I

 

1 Cross Reference Number (on unit): Mark 17X-117.

2 Use TP-390 adaptor to attach the replacement board to the original harness.

3 When replacing the wire harness, the circuit board will also need to be replaced with a TP-351A circuit board and a TP-390 adapter.

4 Refers to the first 10′ section of tubing downstream of burner.

Pressure Switches

BTU/H Range (x1000)50-100125-150175200
Switch 15Part NumberTP-264BTP-264DTP-264DTP-264C
X-Ref., IS220--10051F5166-20051F5170-20051F5170-43051F5172
Normal SettingOpenOpenOpenOpen
P. S. Tube SetTP-AK3TP-AK3TP-AK3TP-AK3
Switch 25Part NumberTP-260FTP-260FTP-260GTP-260G
X-Ref., IS220--62502F5176-62502F5176-62052F5175-62052F5175
Normal SettingClosedClosedClosedClosed
P. S. Tube SetTP-AK4TP-AK4TP-AK4TP-AK4

5 Pressure switch #1 is electrically first in the series, and pressure switch #2 is electrically second in the series.