Factory Direct Re-Verber-Ray Replacement Parts
Current processing time is 3-5 business days. Due to delays with our shipping partners, delivery times can not be guaranteed.
USE CODE 'WINTER10' FOR 10% OFF
Re-Verber-Ray Tube Heater Parts
Detroit Radiant Products Company offers the most extensive line of low-intensity infrared radiant tube heaters available. From our award-winning, engineered vacuum systems to our patented, two-stage line of heaters, you’ll find a product that ideally suits your needs. Re-Verber-Ray® low-intensity heaters are a little- to no-maintenance, cost-effective and energy-efficient solution for heating a wide variety of areas.
RE-VERBER-RAY HL SERIES TUBE HEATER (Manufactured 05/04/95 to 09/95)
Contact the factory for additional parts.
Common Components
| ||
Part Description | Original Part Number | Replacement |
Fan | TP-55A | TP-55A |
Pressure Switches | See Below | See Below |
Circuit Board1,2 | TP-211 | TP-211A2 |
Wire Harness (Glo-Bar and Flame Rod Only) | TP-214 and TP-222A | TP-214 and TP-222A |
Relay (Note: This factory installed option is not on all units) | HLRB | TP-825 |
Ignition Device | TP-50 | TP-50A |
50-100 MBH Burner | TP-200A | TP-3072 |
125 MBH Burner | TP-201 | TP-3072 |
150-200 MBH Burner | TP-201 | TP-201B |
Natural Gas Valve | TP-840 | TP-840A |
Propane Gas Valve | TP-841 | TP-841A |
Transformer | TP-826 | TP-826 |
Indicator Lights | TP-828 | TP-828 |
Flame Rod (whole kit=TP-FRK)3 | N/A | Add TP-FRK |
16″ Burner Tube | TP-202 | TP-380 |
Combustion Chamber4, 50-125 MBH (Aluminized Steel) | TP-26A | TP-26A |
Combustion Chamber4, 150-200 MBH (Titanium Coated Steel) | TP-26B | TP-26B |
Combustion Chamber4, 75-150 MBH (Stainless Steel) | TP-26E | TP-26E |
Radiant Tubes | TP-26A | TP-26A |
10 ft. Reflector Section | TP-20C | TP-20C |
Baffle | TP-65I | TP-65I |
1 Cross Reference Number (on unit): Mark 17X-24.
2 Circuit board replacement requires the rewiring of the flame rod into remote sense. Consult the factory for assistance.
3 TP-FRK includes the gasket (TP-221), flame rod (TP-222), and flame rod wire (TP-222A).
4 Refers to the first 10′ section of tubing downstream of burner.
Pressure Switches | |||||
BTU/H Range (x1000) | 50-100 | 125-150 | 175 | 200 | |
Switch 15 | Part Number | TP-264B | TP-264D | TP-264D | TP-264C |
X-Ref., IS220- | -10051F5166 | -20051F5170 | -20051F5170 | -43051F5172 | |
Normal Setting | Open | Open | Open | Open | |
P. S. Tube Set | TP-AK3 | TP-AK3 | TP-AK3 | TP-AK3 | |
Switch 25 | Part Number | TP-260F | TP-260F | TP-260G | TP-260G |
X-Ref., IS220- | -62502F5176 | -62502F5176 | -62052F5175 | -62052F5175 | |
Normal Setting | Closed | Closed | Closed | Closed | |
P. S. Tube Set | TP-AK4 | TP-AK4 | TP-AK4 | TP-AK4 | |
5 Pressure switch #1 is electrically first in the series, and pressure switch #2 is electrically second in the series.